Call at +17759004070

Leave a message Gia@tmaxlaboratory.com

banner
Products
Home Lab Furnace

CVD Furnace

VS-0.1 Vacuum System with VRD16 Vacuum Pump for CVD System

VS-0.1 Vacuum System with VRD16 Vacuum Pump for CVD System

Sales Manager: Gia

Email: Gia@tmaxlaboratory.com

Wechat: Dingqiuna


  • Item No.:

    TMAX-0.1vacuum
  • Payment:

    L/C, T/T, Western Union, Credit Cards, Paypal
  • Shipping port:

    Xiamen Port
  • Lead Time:

    5 Days
  • Certificate:

    CE, IOS, ROHS, SGS, UL Certificate
  • Warranty:

    Two years limited warranty with lifetime technical support
Product Details

Vacuum System with VRD16 Vacuum Pump for CVD System 



I. Overview

 The system (can pump the vacuum in the tube furnace to 0.6Pa) consists of a suction flange (self-made) with KF25 interface, high vacuum baffle method, resistance vacuum gauge, bellows, bracket (homemade), vacuum pump Connect the tee pipe at the flange outlet, connect the resistance silicon to one end of the three-way pipe, connect the high vacuum flapper valve to the other end, connect the flapper valve and the vacuum pump with the corrugation of Dia25, and use the KF25 quick clamp for the connection port. .

  

2. Pressure detection system

   ZDR-I/ZDR-I-LED type single resistance vacuum gauge

     The resistance vacuum gauge (also known as the Pirani vacuum gauge) uses a specially stabilized ZJ-52T resistance gauge and applies a new constant temperature operation mode to the constant power. At the same time, the microprocessor is used to control the nonlinearity of the regulation. Linear processing. It has the characteristics of stable performance, wide measuring range, fast response and small drift. And powerful and reliable microprocessor-based relay control, serial communication output, vacuum analog output and other functions. Particularly suitable for rough and low vacuum measurement and control of vacuum applications.

Technical Parameters:

* Distribution regulation: ZJ-52T resistance gauge

* Measuring range: 10 5~10 -1 Pa

* Number of measurements: 1 way

* Number of control channels: 2 roads can be extended to 4 or 8 roads

* Control range: 5 × 10 3 ~ 5 × 10 -1 Pa

* Control mode: relay contact output, load capacity AC220V/3A (or DC28V/3A) non-inductive load

* Power: 90-260V/50Hz or 220V ± 10% 50Hz

* Power consumption: 25W

* Weight: 4Kg/3Kg/0.5Kg (depending on the chassis)

* Chassis size: 240 × 88 × 280 or 265 × 119 × 280 or 96 × 96 × 120

480 × 88 × 280 or 480 × 119 × 280 (width × height × depth)


Performance characteristics:

*LED green screen digital display.

* Wide range of star surveys

* Fast response speed

* Microcomputer correction regulates nonlinearity and reduces measurement errors.

* Optical isolation, digital filtering, enhanced anti-interference ability.

* PVC color panel, beautiful appearance.

* Point control or area relay control output, while the set point has power-down protection memory function.  

 

3. Adopt VRD16 vacuum pump

VRD16

Technical term

Specification

VRD-16

Pumping speedm³/h(L/s)

50Hz

16 m³/h

4.4 L/s

60Hz

19.2 m³/h

5.2 L/s

Limit partial pressure - no gas ballast(Pa)

4x10-2

Limit total pressure - no gas ballast(Pa)

4x10-1

Limiting total pressure - gas ballast(Pa)

8x10-1

power supply

Single phase/three phase

motor power(KW)

0.75 KW/0.55 KW

Inlet/outlet connectionDN

KF25

oil capacity

0.9-1.5 L

motor speed(rpm)

50Hz

1440 rpm


vacuum system

 Tmax CE

 TMAX Partner

CVD furnace


tube furnace


muffle furnace



1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

3 Responsible for the damage during the shipping process, will change the damage part for you for free.



related products
Lab 1200C Single Zone Tube Furnace CVD System -Tmax
Lab 1200C Single Zone Tube Furnace CVD System

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

CVD System
Lab CVD System with 1500-1500C Dual Zone Rotary Tube Furnace

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

1600C CVD Furnace with Gas Supply System and Vacuum System -Tmax
1600C CVD Furnace with Gas Supply System and Vacuum System

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

1600C CVD Furnace with Gas Supply System and Vacuum System -Tmax
1600C CVD Furnace with Gas Supply System and Vacuum System

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

RF Power Supply for PECVD -Tmax
RF Power Supply for PECVD

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

1200C CVD Furnace
Lab 1200C Single Temperature Zone Quartz Tube CVD Furnace with 440mm Heating Section

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

Pressure Controlled Polishing Machine
12" Pressure Controlled Auto Lapping and Polishing Machine with Optional Auto Slurry Feeder

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

Film Coater
Lab Vacuum Wire Bar Film Tester Coater Coating Machine

Sales Manager: Gia Email: Gia@tmaxlaboratory.com Wechat: Dingqiuna

© Copyright: 2024 Xiamen Tmax Battery Equipments Limited All Rights Reserved.